Skip to main content

S-03

Lighting control systems

Scene, schedule, occupancy and daylight control over KNX or DALI, integrated with the BMS for one view of the building.

S-03 / 01

Overview

Good lighting control saves energy without anyone noticing it. We design and program scene, schedule, occupancy and daylight control on KNX or DALI, and integrate it with the BMS so lighting status, faults and energy appear alongside every other system.

S-03 · SYNEX

Scope of work

  • Lighting control design per zone: scenes, schedules, occupancy and daylight
  • KNX and DALI device selection, addressing and programming
  • Keypads and touch panels for meeting rooms, lobbies and hospitality
  • Landscape, façade and car park lighting schedules
  • Emergency lighting monitoring where supported
  • BMS integration for status, alarms and energy

Deliverables

  1. 01Zoning drawings and control matrix
  2. 02Device schedules and addressing plan
  3. 03Programmed system and project file backups
  4. 04Scene settings agreed with the client
  5. 05Test records and user guide

Protocols and technologies

  • KNX
  • DALI-2
  • BACnet gateway
  • Occupancy & daylight sensors

Typical applications

  • Offices and meeting rooms
  • Hotels and hospitality
  • Façade and landscape
  • Car parks

How we deliver it

  1. 1

    01

    Survey

    We walk the site, review drawings and the BOQ, and agree what the system must do before anything is priced.

  2. 2

    02

    Design

    System architecture, points list, controllers and network, sized to the real equipment and the consultant's specification.

  3. 3

    03

    Engineering & submittals

    Shop drawings, panel layouts, wiring diagrams, sequences of operation and data sheets, submitted as one complete package.

  4. 4

    04

    Supply & installation

    Controllers, field devices and panels supplied to the approved submittal, installed and terminated under our supervision.

  5. 5

    05

    Programming & integration

    Sequences, graphics, alarms, trends and third-party interfaces are programmed and tested in-house before we reach site.

  6. 6

    06

    Testing & commissioning

    Point-to-point checks, functional tests and witnessed commissioning, with every result recorded.

  7. 7

    07

    Handover & support

    As-built documents, backups and operator training, followed by maintenance and support contracts.

RFQ · SYNEX

Discuss your project with an engineer

Share your drawings, BOQ or specification and we will reply with a clear scope and quotation.